<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-26 13-34-41
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 5/5, 56 dBuV VOLTAGE
Pilot RDS Phase Difference
6.5 kHz 4.0 kHz -10 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
13 kHz 72 kHz 10040 0,3785
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
6,8 dBr 7,66 dBr 8,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 13:34, 26.05.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (55 dBuV) Max at: 72 kHz MIN: 13 kHz % above 75 kHz: 0,3785 Acquired: 2025/05/26 13:33:37 Total samples: 10040 Equivalent time: 0:08:22 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 8,2 dBr MIN: 6,8 dBr AVE: 7,66 dBr % above 10,2 dBr: 0,0 Last value: 7,3 dBr (2025/05/26 13:33:37) Station: 96.90 MHz, signal: 5/5 (55 dBuV) 13:27 13:28 13:29 13:30 13:31 13:32 13:33 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality